There are currently no product reviews.
;
Thank you for providing this manual and at low cost.
The Philips scope is of excellent quality, longevity and build and had a couple of faults
when it was passed to me. Having the CCT diagrams is a blessing.
I have fixed the problems and also modded the scope to my requirements.
I have built a 24v Li-Ion pack for portable use from old but good laptop batts.
it is working beautifully and I am well pleased. Keep up the good work Guys.
;
manual was very helpful in learning how to propery use my washer. I could not find this manual anywhere else.
;
Awesome quality manual. You really saved my bacon with this one. Was looking for some specific information with regards to my "new" vintage VCR that didn't come with the owners manual. This site is truely a goldmine of available manuals. The quality of the scans are top notch.
Thank-you so much for this awesome manual. If you're looking for this Sony SL-HF400 owners manual, this is the one you NEED to buy. Definitely worth the money.
;
The manual was made available promptly. I is a clean scan of the original. I had no problem downloading it. The scan was well centered and cleanly formatted. It is as good a product as can be had without being the original document.
;
Received downlink in less then 8 hours, Item was in good copy condition, and told me how to program the clock timer. The price was very resonable, and the process was very automated and was GREAT to work with.
parameters - the use of a duplicate program name should be avoided. If either error situation occurs, an error message will be given, otherwise an OK message will be given. Request Keygroup Data F0, 47, cc, RKDATA, 48, pp,pp program number kk keygroup number F7 eox If the keygroup number is higher than the highest keygroup in the program, an error message will be given instead of data. Keygroup Data F0, 47, cc, KDATA, 48, pp,pp program number kk keygroup number ln,hn first byte of data in low/high nibble form (see below) ln,hn second byte ...etc. F7 eox This a bidirectional message. In the case of transmitting to the S1000, if the keygroup number is above the highest existing keygroup number, a new keygroup will be created if a block is free, otherwise the existing keygroup will be replaced. The use of program number 255 is a special case where the keygroup data will be installed in program previously created. This avoids the need to read the program list to find out what number was allocated to that program. If there are no free blocks for a new keygroup, an error message will be given. Request Sample Data Header F0, 47, cc, RSDATA, 48, ss,ss sample number F7 eox If the sample number is higher than the highest sample in the S1000, an error message will be given instead of data. Sample Header Data F0, 47, cc, SDATA, 48, ss,ss sample number ln,hn first byte of data in low/high nibble form (see below) ln,hn second byte ...etc. F7 eox This a bidirectional message. In the case of transmitting to the S1000, if the sample number is above the highest existing sample number, a new sample will be created (if a blocks is free and the sample length specified in the header is not too great) and this should be followed by the appropriate sample data packets. If the name in the data is the same as that of an existing sample, it will be deleted first (preceeded by a standard dump WAIT message). If the sample number is of an existing sample, the existing data will be replaced but the sample length parameter SLNGTH must be correct. This allows complete freedom to change parameters - the use of a duplicate name should be avoided. If a new sample cannot be created, an error message will be given, otherwise an OK message will be given. On receipt of a sample header which creates a new sample, the S1000 will behave as if it has received a standard MIDI dump header and if standard MIDI dump is to be used, the data packets should follow immediately. Alternatively, the data can be delivered after an ACCEPT PACKETS command which gives greater flexibility.